Thermal diagnostics, Ecodesign energy labelling, EN 378 leak & pressure tests and optimisation studies in climatic chambers down to -50°C.
AB 308
ILAC MRACOCH Kraków specialises in comprehensive low-temperature testing in modern cold and climatic chambers — from standard performance checks to advanced optimisation studies, aligned with client specifications and key industry standards including EN 378.
Tests focus on detailed analysis of thermal characteristics, cooling capacity and power consumption. We also perform the complete range of testing necessary for product energy labelling, which manufacturers need to meet European regulatory requirements. Certified climatic chambers allow simulation of climatic zones and extreme environmental conditions.
Operating parameters and temperature resistance of deep-freeze installations and cabinets are assessed with reference to EN 378. Leak and pressure strength tests of refrigeration circuits follow PN-EN 378-2 / PN-EN 14276.
Work is covered by PCA AB 308 accreditation with ILAC MRA recognition — reports are accepted across the ILAC zone without repeat testing abroad.

Full suite of analyses in cold and climatic chambers — performance, labelling, EN 378 integrity, mapping and safety.
We carry out standard tests and advanced optimisation research according to individual client requirements and industry standards. Comprehensive low-temperature testing gives a clear view of system performance and practical steps to improve energy ratings.

High-precision measurements of performance and heat loads across the full operating cycle in controlled climatic chambers.
The full pathway of tests required to classify and label commercial refrigeration and heating equipment for the EU market.
Engineering analyses aimed at raising the coefficient of performance and reducing operational energy consumption.
Multi-point mapping to verify thermal stability and homogeneity inside cold storage volumes and cabinets.
Laboratory verification supporting safe market entry under LVD, Machinery, EMC, Ecodesign and related directives.
Electrical safety and insulation tests of refrigeration appliances, control cabinets and drives supporting the Polish B safety mark.
Tightness and pressure strength tests of refrigeration circuits per PN-EN 378-2 / ISO 5149-2 / PN-EN 14276 — required under F-gas and PED.
Independent performance comparison of equipment from different suppliers or design variants.
Independent certified laboratory opinions serving as technical evidence in commercial and market proceedings.
Bespoke measurement schedules tailored for R&D projects, with chamber temperature and humidity set to agreed limits.

Operating parameters of refrigeration installations under controlled laboratory conditions.

Accredited performance and energy tests of commercial refrigeration cabinets.

LVD, B-mark and energy-consumption tests for refrigeration and HVAC equipment.
This service has no public download forms. Contact the laboratory by email, use the contact page, or place an order through the order portal.
Write to us about the service scope, sample delivery and timeline. We prepare an individual quote after the enquiry.
Prefer the order portal for a structured request, or the contact page for general laboratory enquiries.
Key facts about low-temperature chamber testing, EN 378 and energy labelling at COCH Kraków.
COCH Kraków is the only body in Poland authorised to issue ATP certificates. PCA accreditation AB 308 with ILAC MRA recognition guarantees international acceptance of all test reports and certificates.

PCA · ILAC MRA · ACCREDITATION
The laboratory holds PCA accreditation with ILAC MRA international recognition. Certificates issued by COCH are mutually recognised by all signatory countries of the ATP Agreement worldwide.
Arrange accredited low-temperature testing or ask a technical question.
Location & Directions
Centralny Ośrodek Chłodnictwa „COCH”
ul. Juliusza Lea 116, 30-133 Kraków
Laboratory open Mon–Fri, 7:00–15:00
SEMI-TRAILER ENTRY: GATE NO. 2
Last updated:
Contact our specialists to discuss chamber testing down to -50°C, EN 378 integrity checks or energy labelling.